Sign In | Join Free | My chinaqualitycrafts.com
China Shandong Chuangkang Biotechnology Co., Ltd. logo
Shandong Chuangkang Biotechnology Co., Ltd.
Shandong Chuangkang Biotechnology Co., Ltd.
Active Member

2 Years

Home > Negative Pressure Wound Therapy Device >

Drainage Negative Pressure Wound Therapy Device Medical DC 14.8V 5000mAh Battery

Shandong Chuangkang Biotechnology Co., Ltd.

Drainage Negative Pressure Wound Therapy Device Medical DC 14.8V 5000mAh Battery

Brand Name : Chuangkang

Place of Origin : Jinan

MOQ : 1 sets

Price : US$1000-US$3600

Payment Terms : T/T

Delivery Time : Within 7--15 Days for Common Size

Packaging Details : Carton

Certification : CE, ISO13485, FDA

Medical device advertisement approval number : 20183661697

Types of medical device regulation : China's national machinery is approved for 20183661697

Medical device registration (filing) number : HD601492860001

Application : Hospital, Clinic, etc

Sample : Free

Contact Now

High Quality Negative Pressure Wound Therapy Instrument With Drainage Dressing Set

Product Parameters
Model ZN50
Adapter input 100-240VAC 50/60Hz 2.0-1.0A
Adapter output 20VDC 8A
Maximum suction flow 8L/min
Type of safety protection BF type
The battery specification DC14.8V 5000mAh
Waterproof level IPX0
Device dimensions 300mm x140mm x 280mm
The host weight 3.5Kg
Pressure output range -30 to 180mmHg(4-24Kpa)
Working time 5min
The intermittent time 2min
Control the pressure fluctuation range Rated value ±10mmHg(1.33kPa)
Pressure accuracy error Less than ±10%

Product Description

Electric Negative Pressure Wound Therapy System Pump is a negative pressure drainage device for treating various breached or compromised surface wounds only used with Negative Pressure Wound Therapy System Dressing Sets. By generating regular intermittent negative pressure to create conditions for surgical repair.

Electric Negative Pressure Wound Therapy System Pump is portable and consists of main body(including an electric Negative pressure pump, PCBA, Rechargeable Battery), accessories( including Negative pressure Bottle, Power Adapter) and software.
There are two works style: pre-set work style, and physician setting work style. The pre-set work style is for conventional medical operation while physician setting work style is for medical staff to do clinical study.
The negative pressure value of conventional medical operation of the device is 80-120mmhg (10.66-15.99kPa). Under physician setting work style, the medical staff can freely adjust vacuum pressure from 4kPa to 24kPa (30-180mmHg) at 1mmHg (0.13kPa) step.
The digital display shows that the long-life negative pressure pump is adopted, which can run continuously for a long time, with noise less than 55dB, no pollution, air flow rate of 6-12L/min, and high work efficiency.

Electric Negative Pressure Wound Therapy System Pump is used with wound dressings to therapy wound. When the pump is turned on, the user will have 6 fix modes to choice to be suitable for different wound therapy. Also the user can use 7th physician-made mode, which negative pressure ranges from 30-180mmHg(4-24Kpa). All modes are intermittent therapy with 5min suction and 2min rest.
The device is programmed to work, and has notice functions as low voltage, tube/wound sealing air leak alarm, over-higher pump work
temperature.

Instructions for use

  1. Please read the manufacturer's instructions in detail and follow the instructions before using.
  2. Keep away from children, pets, pests, dust and lint because they may damage this device and/or affect its performance.
  3. Medical staff should be trained professionally prior to use this device
  4. Before starting the machine, be sure to no loose or leaking in every part or part joints.
  5. The main body should be kept dry. Do not wash in water. Should not be used in wet or splashed water environment.
  6. Do not operate this device if it has a damaged power cord, power supply or plug. If these components are worn or damaged, contact your local distributor..
  7. Do not drop or insert object into any opening or tubing of this product.
    Do not try to modify this product without authority permission.
  8. Do not connect this product to other devices that are not produced by our company.
    Do not spill liquid on any part of this product. In case of this happen, unplug the adapter if plugged in, then clean the liquid from this product. Ensure there is no liquid and nothing abnormal when starting the test machine. Otherwise, contact your local distributor.
  9. Do not use and/or store this product in or near these places where it can fall or be pulled into a tub, shower, bath, sink or toilet.
  10. Do not reach for this product that has fallen into water. Unplug the unit immediately if plugged in. Disconnect the unit from dressing and contact your local distributor.
  11. Cell phones or similar products could affect this product. Move this product away from these devices if interference is suspected.

The user must read the manual carefully before using the product.

Product acessories
Check that the probe and sealing plug of the negative pressure bottle should not be skewed, and slowly and horizontally push the negative pressure bottle into the installation position of the main body
 
Long press "shift mark/modify" button to check the working parameters of the equipment
Line 1: Display battery voltage (the power switch is on AC, this value is 0)
Line 2: Display the working current of the negative pressure pump (real-time monitoring of the negative pressure pump current, immediately stop the machine for protection if there is any abnormality)
Line 3:Display negative pressure pump temperature (real-time detection of negative pressure pump temperature, temperature above 36ºC will automatically open scattered
Hot fan, over 70ºC,Negative pressure pump shutdown protection)
If there is a sudden loss of pressure during the using of the machine, there is no need to worry that the liquid in the negative pressure bottle will flow back to the patient's part, because there is a duckbill valve device in the negative pressure bottle, which stipulates that the liquid can only flow from the outside of the negative pressure bottle to the inside of the negative pressure bottle, because its positive opening pressure is very low, and the reverse pressure is very high, so there will be no backflow
 

Replacement of negative pressure bottle

Remove : remove the negative pressure bottle from the left side of the machine, palm up, hook the handle of the blue cover of the negative pressure bottle with the index finger and middle finger of the left hand, hold the thumb against the shell, and pull it horizontally to the left slightly to take out the negative pressure bottle, as shown in the figure below

Installation: prepare the new negative pressure bottle, connect one end of the elbow of suction connection pipe to the suction port of the negative pressure bottle, and insert the negative pressure bottle buckle with the left palm to the negative pressure bottle cavity of the machine

Remove the battery fixing screw from the back shell of the machine with a cross screwdriver; Use thumb, index and middle finger cards
Live the battery buckle pull ring, thumb and index finger to close together; At the same time, the wrist is pulled outward in the direction perpendicular to the battery, that is, the battery can be removed, and a new battery can be replaced in the opposite way and be put into the machine

working principle

This device stores 6 commonly used negative pressure closed drainage treatment programs and a user-definable negative pressure treatment program in CUP of mainboard. When the power is turned on, a command is input from the therapeutic device screen and a treatment program accordingly. Then a driving circuit on the main board generates a certain frequency of current to act on the negative pressure pump to generate a negative pressure. During operation, the pressure sensor detects and monitors the negative pressure change, at same time these negative pressure information is transmitted back to the CPU. Through this dynamic control, the working frequency of the negative pressure pump is continuously kept relatively stable preset-value, thereby achieving the effect of negative pressure treatment.

Applications

Electric Negative Pressure Wound Therapy System Pump is intended to deliver negative pressure via the Negative-pressure Wound Therapy System Dressing Sets to the breached or compromised surface wound, in order for the removal of fluids, including wound exudates, irrigation fluids, body fluids and infectious materials, and is used only in hospital environment, not for civilian, household, ambulance and field hospital.

The device is applicable to the following treatment areas:
Acute wound.
Chronic and refractory wounds.
Wound surface requiring drainage due to excessive fluid leakage after surgery.

The device is forbidden use in such wound as:
Undebridable wound with necrotic eschar
Wounds with tumor tissue.
Fistula communicating with internal cavity viscera.
Wounds with large blood vessels or organs exposed.

Warranty Commitment


The company promises to provide warranty service within one year from the date of purchasing the equipment produced by the company. If the product itself has quality problems, the company has the right to choose to repair or replace the product without adding any cost to the user.
The company will not be jointly and severally liable for product damage caused by abuse, accident, improper operation or violation of instructions for use. The customer must return the warranty registration card to the company within 30 days after the product is damaged, otherwise it will be deemed invalid. Information such as invoices and product serial numbers must be filled in. The warranty card is limited to the original purchaser and cannot be transferred.

FAQ

1. What is the advantage of quality?
The company is furnished with developed equipment and technology from Germany, Belgium, and Taiwan (area).

2. What is MOQ?
30,00 pcs, It depends on the requirements of the products.

3. How to place an order?
Place an order with the salesperson
Make payment for deposit;
Sample making for confirmation before mass production;
After the sample is confirmed, mass production starts;
Goods are finished, inform the buyer to make payment for the balance;
Delivery.
Production time: 30-40 days.

4. What is your term of payment?
T/T is a regular payment (30% in advance, 70% before shipping).
Paypal and Western Union are just for a sample


Product Tags:

Battery Negative Pressure Wound Therapy Device

      

DC 14.8V Negative Pressure Wound Therapy Device

      

Medical Wound Drainage Devices

      
Quality Drainage Negative Pressure Wound Therapy Device Medical DC 14.8V 5000mAh Battery for sale

Drainage Negative Pressure Wound Therapy Device Medical DC 14.8V 5000mAh Battery Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shandong Chuangkang Biotechnology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)